Custom Build Products

 
 
MCC & PCC
 
Specifications & Features
• Customize MCC, PCC enclosures as per need
• 100% modular structure, can be dispatched in flat pack
• Flexible horizontal / verticle busbar & cable compartment configuration
• Compartmentalised - uppto from 4
• IP 54 with polyurathene foam gasketing
• Doors available in height of 200mm & multiplies of 100mm
• Plinth (modular) and side cover is optional
• Additional accesories like cable support, busbar support & baying kitare available as an option
• Manufaturing plate adjetable throught the feeder compartment depth at an pitch of 25mm
• BB chamber (Top/Bat) & feeder doors (left/right) are inter changeable
• Panel can be expanded in all 3 dimensions & bayed together by using baying kit
• 11 tank fully automated pretreatement
• Colours: RAL- 7032 (structure finish) for structure, covers, & doors. RAL-2000 (smooth finish) for manufacturing plate, RAL-9000 (smooth finish) for Plinth & Lifting channel
• Sheet thickness 2mm CRCA for stucture, Manafcturing Plate & Manufacturing Rail, 1.6mm CRCA for covers & doors, 1.2mm CRCA for separation plates.
 
 
Crane Control Panels
 
Crane Control Panels (AC)
 
This controller provides reserving and plugging operation of slip ring induction motors in heavy duty crunes on trooley services. Upto 5 motor speeds are achieved in conjuction with a master controller
 
Specifications & Features
Hoisting Motion Bridge and Trolley Motion
• Plain rotor resistance • Simplified reliable circuitry
• AC Single phase dynamic braking • Inverse Time delay Magnetic Overload protection
• Counter torque lowering • Time limit acceleration
• Discontainer • Speed Control by series resistors
• Creep Speed • CRCA Sheet steel bolted type construction of the panel
  • 11 Tank pretreated panels for extremely long life
  • Panels for indoor and outdoor protection
 
 
DC Crane Control
 
DC Crane Control
 
This control is for use ith series wound motors drive for crane hoists and is arranged for reserving and dynamic lowering service control
 
Specifications & Features
Bridge and Trolley Motion Hoisting Motion
• Simplified, reliable circuitry • Simplified reliable circuitry
• Rectifier controlled plugging • Inductive time limit acceleration on hoisting & lowering
• Instantaneous and Inverse time delay magnetic overload protection • Beller speed control on light or heavy loads when hoisting or lowering
• No volt protection • CRCA Sheet steel bolted type construction of the panel.
• Heavy duty DC Contactors equipped with magnetic blowouts • 11 Tonk pretreated panels for extremely long life
• CRCA Sheet steel bolted construction of the panel  
• 11 Tonk pretreated panels for extremely long life  
 
 
Punch Grid Resistors & Panels, NGR & DBR
 
Punch Grid Resistors & Panels, NGR & DBR
 
Range
• Speed Control Resistors
• Starting Resistors for AC and DC Motors
• Dynamic Braking Resistors
• Neutral Grounding Resistors (upto 11 KV)
 
Specifications & Features
 
• Special Chromiun Steel Alloy (AISI406) for:
a) Higher resistivity (approx 70% higher than others) This results in overall light and compact unit
b) Low temperature coefficient ( approx 72% lower than others)
 
This means negligible change in resistance values despite grid temperature variations (very important parameter in
applications like crone controls)
 
Special Purpose Starters
 
Special Purpose Starters
 
Specifications & Features
 
• Direct ON line Starters upta 500 HP
• Star Delta Starters upto 650 HP
• Closed Transition Star Delta Starters upto 650 HP
• Automatic Stator Rotor Starting Panels upto 1000 HP
• DC starter upto 600A
 
APFC Panels
 
APFC Panels
 
3Phase Automation Power Factor Correction (APFC Panels)
 
Specifications & Features
 
   
• advanced Micro Controller based Power Factor Controller with Self-diagnostic Sensing and Control of Capacitor Bank Stages • Choice of selection of Capacitors as per application & site conditions
• High performance 'BCH' Cylindrical & Box type
Capacitors
• Thoughtfully designed Panels with provision for louvres & cooling fan for proper ventilation to manage heat
load
• Capacitor duty Contactors for reliable & trouble free operation • Enclosure with Epoxy based paint shade RAL 7032 and mounting plates with RAL 2000
• Choice of Bhartia-Celduc's world class Solid State Relay (SSR) with TMS2 technology as an option • PU Foam Gasketing for sustained Ingress Protection of the Panel
 
APFC Panels
 
APFC Panels
 
Specifications & Features
   
CAPACITOR RATING 40 to 200KVAr in Standard Ratings of 40, 50, 60, 75, 100, 125, 150, 175 &
200 KVArwith suitable banking arrangement
MOUNTING Wall Mounting up-to 75KVAr& Floor Mounting above 75 KVAR ratings
INCOMING BCH-TERASAKI 3-P MCCB with Rotary handle
OUTGOING TP MCB or HRC fuses with fuse base as standard (BCH-TERASAKI 3-P MCCB or
SDFU and Compartmentalized outgoing feeders can also be provided
depending upon size of panel on request)
CONTACTORS BCH Capacitor Duty Contactors as standard (BCH-Celduc SSR's on request).
R-Y-B INDICATIONS BCH Flexi-22 LED's
AMMETER/VOLTMERS Provided for VERSIONS 3, 4 & 5 only
 
Power Receptacles
 
Power Receptacles
 
Specifications & Features
   
• Single / Multiple outlet boxes
• Modular and compact construction
• 16/32/63/125A rating
• Loop-in & Loop out facility
• With or without protection
• Higher degree of Ingress Protection
• Option of back up protection with:
• 11 Tank processed powder coated enclosure
MCBs
• PU Gosketing for excellent sealing against dust and water
SDFUs
MCCBs
 
Auto Transformer Starters
 
Auto Transformer Starters
 
Good Starting Torque and current performance
Possibility of adjusting starting parameters
No break in supply to the motor during starting
Best suited when maximum reduction of Inrush current is desired or
motor requires longer acceleration time with Good starting torque
• Blowers
• Pumps
• Com pressors
• Extruders
• Crushers
 
Specifications & Range
• Available upto 800HP
• Standard Toppings: 50%,65% and 80%
• Air Cooled design
• 11 Tank pre treated bolted construction enclosure
• Superior gasket
 
Protections
• Short Circuit
• Overload and Single Phasing (Thru Overload relay)
• Under voltage
• Other pratections available on request
 
Metering & Indication
• Voltmeter with selector switch
• Ammeter with selector switch
• R,Y,B phase indication
• Motor ON, OFF and Trip indication
 
Auto Transformer Starters
 
Battery Charger Panels
 
• Floot-cum-Boost 24V/48V, up-to 25A/200AH
• Float and Boost 24V to 220V DC, upto 3000AH
 
Specifications & Features
• Voltage regulation + 1% for 0-100% load variation & for + 10% incoming voltage variation
• Stepless variation of output voltage in case of float & boost
• Battery is automatically connected to the load thro' contactor, in case of powerlailure
• Current limit adjustoble from 0-200%
• Blocking diode in individual converter output
• In case of float & boost, 8O% tapping diode ensures 8O% output voltage with static switching action
• Filter circuit to reduce ripple content
• Auto changeover from boost to float & vice versa
• Audiovisual fault annunciation with alarm for (a) under voltage, (b) over voltage & (c) earth fault
• Mode of boost charging (a) constant voltage mode & (b) constant current mode
• Meters & Indications
 
 
Applications
• Power Stations
• Substations
• Process industries like Paper, Cement, Steel, Chemicals & Fertilizers
• Telecommunication
• Railways
 
'Responder 200' Analogue A. C. Drive panels are also included in the manufacturing program
 
 

Power Contactors || Motor Protection Circuit Breakers || Low Voltage HBC Fuselinks || High Voltage HBC Fuselinks || Switch Disconnector Fuse Switch || Miniature Circuit Breaker || Record Plus MCCB || Spectronic - Air Circuit Breakers || Mpact Mpro || Overhead Busbars || ower Capacitors || UPS Single Phase || UPS Three Phase || Miniature Circuit Breaker ( MCB ) || Miniature Circuit Breaker Changeover || Residual Current Circuit Breakers ( RCCB / ELCB ) || Residual Current Circuit Breakers with Overload & Short Circuit Protection ( RCBO )|| Distribution Boards || Bakelite Fuse Holders || Double Break Fuse Switch Unit || HBC Fuse || HBC Fuse Holder - New || House Service Cutout || Insultated strit light cutout || Moulded Case Ciircuiit Breaker || Moulded Case Ciircuiit Breaker Panel Board || Metal Clad Plug and Socket || Nylon Fuse Base || Off-Load Changeover Switch || On Load Changeover Switch || Rewirable Switch Fuse Unit || Switch Disconnector Fuse (Cubicle Fuse Switch Unit) || Street Lighting Cutouts || Vertical fuse strip & fuse base || Vertical strip fuse base || Wedge type fuse carrier